TEST: QC in the Hot Lab

1.  Which pair of the following systems is suitable for chromatographic determination of radiochemical impurities in Tc-99m MDP?:

        Silica gel/saline for free Tc, paper/acetone for HR Tc

        Silica gel/saline for HR Tc, paper/acetone for free Tc

        20% saline for free Tc, water for HR Tc

        20% saline for HR Tc, water for free Tc

2.  There are four mandatory dose calibrator tests. The geometry test is performed at installation. What is the required frequency for performing the other three tests?

        Accuracy test daily, linearity test weekly, constancy test monthly

        Accuracy test annually, linearity test weekly, constancy test quarterly

        Accuracy test daily, linearity test quarterly, constancy test annually

        Accuracy test annually, linearity test quarterly, constancy test daily

3.  In the Mo-99 Breakthrough test, a technologist first measured the Tc-99m activity of the eluate on the Tc-99m setting using the plastic holder that drops into the calibrator. Then the Mo-99 activity was assayed in the special lead container using the Mo-99 setting. Which of the following is an accurate assessment of how the test was performed?

        The individual steps were performed correctly and in correct order

        The individual steps were performed correctly but in incorrect order

        The individual steps were performed incorrectly but in correct order

        The individual steps were performed incorrectly and in incorrect order

4.     Which of the following is a radionuclide impurity?

        Mo-99 in the Tc-99m eluate

        HR Tc in the Tc-99m eluate

        Free Tc in the Tc-99m eluate

        Unbound I-123 in I-123 mIBG

5.      Which two of the following are NOT radiochemical impurities?

 a.   Aluminum ion in the Tc-99m eluate
  b.   HR Tc in the Tc-99m eluate
  c.   Free Tc in Tc-99m MDP
 d.
Mo-99 in the Tc-99m eluate

        a and b

        b and d

          ac

        a and d

6.   The upper limit of Mo-99 breakthrough for a fission Mo-99 generator is

        0.15 mCi Mo-99/mCi Tc-99m at time of elution.

        0.15 mCi Mo-99/mCi Tc-99m at time of administration

        1.5 mCi Mo-99/mCi Tc-99m at time of elution.

        1.5 mCi Mo-99/mCi Tc-99m at time of administration

7.   The amount of Hydrolyzed Reduced Tc-99m found in preparations of Tc-MAA is ...?

        Typically <1%

        Typically between 1-3 %

        Typically between 5-10%

        Hydrolyzed Reduced Tc-99m in Tc-MAA cannot be determined

8.    Radiochemical impurities are quantitated by

        Dose calibration

        Gamma ray spectral analysis

        Chromotography

        Colorimetry

9.    A technologist performed the Aluminum ion breakthrough test by placing a drop of an aluminum standard solution on one end of the special test paper and a sample of the Tc-99m eluate on the other end of the test strip. The eluate spot turned a medium red color and the standard solution turned the paper a faint pink color. Which of the following is correct:

        The test was performed incorrectly and therefore results are invalid

          The test was positive for aluminum ion breakthrough

          The test was negative for aluminum ion breakthrough

        The test should have been performed using a dose calibrator

10.  For radioisotope dose calibrator quality control tests,

        Measured values must be within 5% of the expected values

        Measured values must be within 10% of the expected values

        Measured values must be within 15% of the expected values

        The value is set independently by each laboratory

                                                               

 

Courses Offered By This Website Are Not Affiliated With or Sponsored by 
Loyola University Medical Center.

Home | NucMedTutorials
Any Questions?? Contact Information
This website is owned and operated by nucmedconsultants@comcast.net
copyright ©2008, Consultants in Nuclear Medicine. All Rights Reserved
2910 W. Estes Chicago, Illinois 60645-2934
Phone: 773/802-7617   Fax: 773/304-2545
web design: maxioms.com

Page Last Updated: February 26, 2008